Heating and cooling systems from the line of process cooling systems in the SUK model series always consist of the compressor, pump, expansion tank, evaporator and condenser modules. Depending on the lowest operating temperature, single-stage (down to -35 °C) or two-stage compressors (down to -50 °C) are used and with very low temperatures two cooling circuits are used in cascade (down to -100 °C). The condenser can be cooled by water or air. The output is continuously and precisely controlled by the injection controller. If multiple compressors are present, stage switching saves energy and ensures low-wear partial load operation (automatic compressor system). With an electric heater or a steam heat exchanger the SUK model series can be expanded for temperatures from -100 up to 150 °C. Also precooling using in-house brine or air can be easily realized using the building kit. The application itself dictates whether a cold storage buffer tank is advantageous or not.

TECHNICAL DATA FOR LAUDA PROCESS COOLING SYSTEMS
Features | SUK 150 W/L(Ex) | SUK 250 W/L(Ex) | SUK 350 W/L(Ex) | SUK 400 W/L(Ex) | SUK 600 W/L(Ex) | SUK 1000 W/L(Ex) |
---|---|---|---|---|---|---|
Heat transfer fluid | Water, water/glycol, thermal oil, special liquids | |||||
Working temperature (°C) | - 40 ... 150 | - 50 ... 150 | - 70 ... 150 | - 100 ... 150 | - 100 ... 150 | - 100 ... 150 |
Pump flow rate (m³/h) | 0,5 … 2 | 2 … 6 | 2 ... 20 | 4 ... 30 | 5 ... 50 | 10 ... 80 |
Heater power (kW) | up to 9 | up to 18 | up to 50 | up to 60 | up to 120 | up to 240 |
Single-stage compressor | ||||||
Cooling output at 20 °C (kW) | up to 10 | up to 20 | up to 50 | up to 150 | up to 300 | up to 400 |
Cooling output at 0 °C (kW) | up to 5 | up to 15 | up to 35 | up to 120 | up to 240 | up to 300 |
Cooling output at - 20 °C (kW) | up to 3 | up to 6 | up to 18 | up to 60 | up to 120 | up to 180 |
Cooling output at - 40 °C (kW) | up to 1 | up to 2 | up to 7 | up to 45 | up to 90 | up to 120 |
Two-stage compressor | ||||||
Cooling output at - 50 °C (kW) | up to 1 | up to 4 | up to 35 | up to 70 | up to 90 | |
Two-stage cascade | ||||||
Cooling output at - 60 °C (kW) | up to 3 | up to 25 | up to 50 | up to 70 | ||
Cooling output at - 70 °C (kW) | up to 2 | up to 10 | up to 20 | up to 35 | ||
Cooling output at - 80 °C (kW) | up to 0,5 | up to 5 | up to 10 | up to 20 | ||
Dimensions min. (mm) | 400 x 800 x 1000 | 500 x 1000 x 1500 | 800 x 1700 x 1500 | 1000 x 1500 x 1900 | 1500 x 2200 x 2000 | 1500 x 2200 x 2000 |
Dimensions max. (mm) | 500 x 1000 x 1500 | 600 x 1500 x 1500 | 1000 x 1500 x 1900 | 1300 x 1900 x 2000 | 200 x 2500 x 2000 | 2000 x 2500 x 2000 |
Features | KH 150 W/L(Ex) | KH 250 W/L(Ex) | KH 350 W/L(Ex) | KH 400 W/L(Ex) | KH 600 W/L(Ex) | KH 1000 W/L(Ex) |
---|---|---|---|---|---|---|
Heat transfer fluid | Thermal oil, special liquids | |||||
Working temperature (°C) | - 40 ... 250 | - 50 ... 250 | - 70 ... 250 | - 100 ... 250 | - 100 ... 250 | - 100 ... 400 |
Pump flow rate (m³/h) | 0,5 … 2 | 2 … 6 | 2 ... 20 | 4 ... 30 | 5 ... 50 | 10 ... 80 |
Heater power (kW) | up to 9 | up to 18 | up to 50 | up to 60 | up to 120 | up to 240 |
Single-stage compressor | ||||||
Cooling output at 20 °C (kW) | up to 10 | up to 20 | up to 50 | up to 150 | up to 300 | up to 400 |
Cooling output at 0 °C (kW) | up to 5 | up to 15 | up to 35 | up to 120 | up to 240 | up to 300 |
Cooling output at - 20 °C (kW) | up to 3 | up to 6 | up to 18 | up to 60 | up to 120 | up to 180 |
Cooling output at - 40 °C (kW) | up to 1 | up to 2 | up to 7 | up to 45 | up to 90 | up to 120 |
Two-stage compressor | ||||||
Cooling output at - 50 °C (kW) | up to 1 | up to 4 | up to 35 | up to 70 | up to 90 | |
Two-stage cascade | ||||||
Cooling output at - 60 °C (kW) | up to 3 | up to 25 | up to 50 | up to 70 | ||
Cooling output at - 70 °C (kW) | up to 2 | up to 10 | up to 20 | up to 35 | ||
Cooling output at - 80 °C (kW) | up to 0,5 | up to 5 | up to 10 | up to 20 | ||
Dimensions min. (mm) | 500 x 1000 x 1500 | 600 x 1000 x 1500 | 800 x 1700 x 1500 | 1000 x 1500 x 1900 | 1500 x 2200 x 2000 | 1500 x 2200 x 2000 |
Dimensions max. (mm) | 600 x 1500 x 1500 | 800 x 1700 x 1500 | 1000 x 1500 x 1900 | 1300 x 1900 x 2000 | 2000 x 2500 x 2000 | 2000 x 2500 x 2000 |
Your advantages at a glance
Digital temperature controller
for controlling the consumer / product temperature and the outflow temperature
Highly dynamic, energy-efficient cooling system
thanks to modern cooling modules for the best possible configuration of compressor and performance quantity
Automatic shut-off valve on cooling water inlet
to avoid contamination of the heat exchanger
Hermetic version without seals
so that oils and water are not mixed
Continuously controlled stainless steel electric heater as a flange version
thus, the heating power is adapted to the actual energy requirements
FAT (Factory Acceptance Test) in presence of customer
to check that the systems are designed for customer requirements and to provide an initial instruction and trial run already before shipment