The optimum technology for your individual needs
Innovative temperature control technology with environmentally friendly refrigerants

Powerful refrigeration technology with natural refrigerants

From compact laboratory thermostats to custom heating and cooling systems for plant engineering, LAUDA is a leading global supplier of precise, sustainable temperature control technology.

Our products are engineered for high energy efficiency and a low CO₂ footprint. This is especially critical since nearly 95% of a product’s lifetime CO₂ emissions occur during the operating life of the equipment.

Wherever possible, we integrate advanced electronic controls and speed-controlled compressor technology as standard features in our refrigeration systems, ensuring optimal performance and significant energy savings. Our high-performance product lines, such as LAUDA Ultracool, deliver up to 50% energy savings compared to conventional technology. We maintain these high standards in production across our entire product range ‒ from laboratory devices to industrial process thermostats.

A cornerstone of our long-established sustainability strategy is the transition to natural refrigerants in our refrigeration technology. For every application and product, we choose the refrigerant that delivers the optimal balance of performance and environmental benefits. This approach continuously reduces our products’ carbon footprint, fully aligning with current regulatory requirements and LAUDA’s sustainability goals.

The European Union’s F-Gas Regulation and other international requirements (such as those of the US EPA) mandate a gradual phase-down of fluorinated refrigerants with high GWP values. These regulations create a strong incentive to develop and implement innovative technologies that use natural refrigerants. By offering a comprehensive range of refrigeration solutions, LAUDA already makes it possible to switch to future-proof, sustainable refrigerants that can be tailored to your individual application needs.

Natural refrigerant solutions at a glance:

What is CO₂ (R744)?

R744 is the official designation for carbon dioxide (CO₂) when used as a refrigerant. This naturally occurring substance does not harm the ozone layer and has a very low global warming potential (GWP of 1) compared to conventional fluorinated refrigerants like HFCs and F-gases. Although classified as non-flammable (A1), R744 requires specialized components and enhanced safety measures due to its high operating pressures. Today, it is widely used for central cooling in supermarkets, commercial refrigeration, specialized industrial systems, and heat pumps.

What is Propane (R290) / ...?

R290 is the official designation for propane when used as a refrigerant. For LAUDA and for the refrigeration and air conditioning industry, R290 is extremely important due to its eco-friendly properties, versatility, and high performance. Like R744, R290 is a naturally occurring refrigerant, with no ozone depletion potential (ODP) and a very low global warming potential (GWP of 3). It is ideal for use in household appliances such as refrigerators, air conditioners, and dryers, as well as in industrial systems ‒ especially in chemical and pharmaceutical applications ‒ thanks to its robustness. Moreover, integrated safety features make R290 easy to install and operate, even in systems requiring larger refrigerant charges. These advantages are also reflected in other A3 refrigerants, such as R170 (ethane) and R1270 (propene).

Your experts for innovative temperature control solutions

Please contact us for individual advice.

Send request now

Comparison of technological solutions at LAUDA

Device with natural refrigerant
R744 = CO₂
Device using natural refrigerants / hydrocarbons
(e.g. R290 = propane)
Device with HFO refrigerants / synthetic F-gases
(e.g. R513A)
Device with HFO refrigerants / synthetic F-gases
(e.g. R455A)
Reference: HFC refrigerants / classic F-gases
(e.g. R134a)
Safety classA1A3A1A2LA1
ToxicityNoNoNoNoNo
FlammabilityNoYesNoLowNo
Danger of asphyxiaYesLowLowLowLow
Specific safety requirementsFor installation in cellars or above ground without emergency exits: Minimum room volumes of the installation site and ventilation if necessary (risk of suffocation in the event of leakage).None up to 150 g refrigerant load. From 150 g refrigerant load: Minimum volumes of the installation location, leakage sensor and ventilation if necessary.NoneNone up to 150 g refrigerant load. From 150 g refrigerant load: Minimum volumes of the installation location, leakage sensor and ventilation if necessary.None
GWP (Global Warming Potential =
CO₂ equivalent)
1< 10< 1 to < 700< 1 to < 700Normally > 1000
COP (Coefficient Of Performance = Ratio of cooling capacity to the electrical power used at full load and tb=20 °C)approx. 3 (single-stage compressor, long-term stability at lower temperatures)approx. 3,6 (decreases steadily at lower temperatures)approx. 3 (decreases steadily at lower temperatures)approx. 3,3 (decreases steadily at lower temperatures)approx. 3,3 (decreases steadily at lower temperatures)
Temperature rangeDown to −45 °C (single-stage)Down to −100 °CDown to −30 °CDown to −50 °CDown to −100 °C
Heat dischargeWater-cooled onlyAir and water cooling possibleAir and water cooling possibleAir and water cooling possibleAir and water cooling possible
ConclusionLimited minimum temperature. High energy efficiency and cooling capacity under ideal working conditions (water-cooled, indoor installation). Additional costs due to higher system pressures. Low safety requirements.Technically ideal replacement for classic F-gases with high energy efficiency. Air and water-cooled design, all temperature ranges can be realized. Established safety technology.Alternative to conventional F-gases. Advantage in terms of low safety requirements (like HFC refrigerants) and can be designed for air and water cooling, but as a fluorinated refrigerant, its use is restricted in the EU. Limited minimum temperature and lower cooling capacity density require larger systems.Slightly reduced, but similar safety requirements to natural A3 refrigerants, lower cooling capacity density requires larger systems for comparable cooling capacity.State-of-the-art technology, high energy efficiency and low safety requirements.

In March 2025, LAUDA received the Silver Rating for Sustainability from EcoVadis. With 70 out of a possible 100 points, LAUDA is among the top 15 percent in its class worldwide and is setting an example for responsible business practices and sustainable corporate management.


Summary

The natural refrigerant R744 (CO₂) excels in applications that require high cooling capacity, indoor installation, outlet temperatures below 0 °C, and a central cooling water supply ‒ offering both energy efficiency and ease of installation.

The natural refrigerant R290 (and other A3 refrigerants), which can serve as a nearly one-to-one replacement for fluorinated refrigerants, is well suited for both indoor and outdoor installations, whether air- or water-cooled. Its high energy efficiency at temperatures above 0 °C, along with integrated safety features for handling larger refrigerant charges, makes R290 a more cost-effective solution in many cases.

Synthetic HFO refrigerants such as R513A, with a lower GWP value, represent a good compromise between conventional F-gases (HFCs) and natural refrigerants and are rightly considered transitional refrigerants. A1/HFO refrigerants offer more limited temperature ranges and lower cooling capacity densities but are easy to use. A2L/HFO refrigerants have higher safety requirements but offer greater cooling capacity density and energy efficiency and can often be implemented as “drop-in refrigerants” in many conventional systems with minimal modifications.

LAUDA offers an extensive portfolio of refrigeration solutions, customized to meet a variety of application needs and installation environments.

Your experts for innovative temperature control solutions

Please contact us for individual advice.

Send request now

LAUDA Integral

Powerful refrigeration technology with natural refrigerants

 

 

LAUDA Integral XT process thermostats operate according to the flow principle with cold oil overlay. In the Integral P versions, a pressure overlay is also possible. This allows temperature control media to be used over a significantly wider temperature range – ideal for dynamic temperature control tasks.

Electronically controlled pumps and optional flow regulators enable a wide variety of operating conditions in complex application scenarios.

All Integral units using CO₂ – as well as all Integral units with more than 150 g of propane refrigerant – are equipped with a quick-stop button and an interface for integration into a central emergency stop system.

 

Specific Key Features of the IN 2040 XTW and PW:

  • Operation with natural refrigerant R744 (CO₂)
  • Speed-controlled compressor for energy-saving partial-load operation
  • No additional flammability sensor required thanks to the CO₂ (R744) refrigerant (A1)
  • Stable cooling capacity across a temperature range of –10 to 30 °C

Propane is classified as an A3 refrigerant. Refrigerant charges of 150 g or more within a refrigeration circuit require a safety assessment at the installation site.

“Safety is not an option” is the guiding principle for the integrated safety concept of the Integral units using propane as a refrigerant. A gas detection sensor integrated as standard continuously monitors the refrigeration circuit for gas leaks once mains power has been established. The unit can only be switched on if the system passes this safety check. If the leak detection system identifies refrigerant during operation, an initial warning is issued depending on the detected concentration. Should the concentration continue to rise, all components are safely and systematically disconnected from the power supply.

“Safety is not an option” – We support the safe operation of your system through a fully integrated safety concept in the Integral XT, saving you the effort of independently developing a risk assessment and searching for suitable accessories, options, or frequently recalibrated gas detection systems. The units can be operated immediately – without additional retrofitting – provided the minimum room size requirements are met.

 

Specific Key Features of the IN 550 XT / 550 XTW / 750 XT / 950 XTW:

  • ATEX-certified gas detection system with warning and shut-off function, plus external status interface for higher-level safety systems
  • Safe start-up through automated leak testing prior to activation of live components
  • Operation with natural refrigerant R290 (propane)
  • Gas detection sensor with 10-year calibration-free operation
LAUDA Integral – IN 550 XT with natural refrigerant


Logistics requirements according to the refrigerant used

Transport byFreon / F-GasNatural refrigerant –
A1 (CO₂)
Natural refrigerant –
A3 (Propane, Ethane, etc.)
HFO –
A1 refrigerant
HFO –
A2L refrigerant
Road
Road
Yes *Yes *Yes, up to 12 kg refrigerant loadYes *Yes *
Air
Air
Yes *Yes *Yes, up to 100 g refrigerant load **Yes *Yes, up to 100 g refrigerant load **
Sea
Sea
Yes *Yes *Yes *Yes *Yes *

* Additional delivery documentation required for systems with > 12 kg refrigerant load.

** LAUDA offers special logistics and service processes for urgent transportation of appliances with > 100 g refrigerant (class A3 and A2L) via air freight.

Local regulation may impose stricter limits or add additional parameters. Please verify your legal obligations.
Any violations on logistic regulations are within the shippers sole responsibility if transport is not undertaken by LAUDA.

 

DO YOU NEED FURTHER INFORMATION OR DO YOU HAVE ANY QUESTIONS?


International Area Sales

+49 9343 503-555 Product inquiry

There are already three products on your comparison list.
To compare other products, please delete one of the products on your comparison list.