The small internal liquid volume and the high power of process thermostats provide for fast heating and cooling: in the air-cooled version, the ambient air is used to cool the thermostating medium, similar to a refrigerator; these are therefore not suitable for the use in very small rooms. The water-cooled version uses existing water connections for thermostating.

Type

Working
temp.
range
(°C)

Temperature
stability
(+-K)

Heating--
power
(kW)

Cooling
output
(kW)

Pump
pressure
max.
(bar)

Pump
suction
max.
(bar)

Pump flow
pressure
max.
(L/min)

Pump flow
suction
max.
(L/min)

Internal
bath
volume
(L)

Bath opening/
bath depth
(mm)

Power
supply
(V; HZ)

Cat.
No.

> Integral XT


LAUDA Integral XT 490 W -90...200 0,1 5,3 4,4 2,9 - 45 - 9,5 - 400; 3/PE; 50 LWP 539
LAUDA Integral XT 280 -80...200 0,1 4,0 1,5 2,9 - 45 - 5,0 - 400;3/PE; 50 LWP 534
LAUDA Integral XT 280 W -80...200 0,1 4,0 2,0 2,9 - 45 - 5 - 400;3/PE; 50 LWP 535
LAUDA Integral XT 350 W -50...220 0,1 3,5 3,1 2,9 - 45 - 5 - 230; 50 LWP 117
LAUDA Integral XT 350 HW -50...300 0,1 3,5 3,1 2,9 - 45 - 5,3 - 230; 50 LWP 119
LAUDA Integral XT 750 S -50...220 0,05 8,0 6,7 2,9 - 45 - 5 - 400; 3/PE; 50 LWP 552
LAUDA Integral XT 750 -50...220 0,05 5,3 6,7 2,9 - 45 - 5 - 400; 3/PE; 50 LWP 520
LAUDA Integral XT 750 H -50...300 0,05 5,3 6,7 2,9 - 45 - 5,3 - 400; 3/PE; 50 LWP 522
LAUDA Integral XT 750 HS -50...300 0,05 8,0 6,7 2,9 - 45 - 5,3 - 400; 3/PE; 50 LWP 553
LAUDA Integral XT 950 WS -50...220 0,1 8,0 9,0 2,9 - 45 - 5 - 400; 3/PE; 50 LWP 554
LAUDA Integral XT 950 W -50...220 0,1 5,3 9,0 2,9 - 45 - 5,0 - 400; 3/PE; 50 LWP 521
LAUDA Integral XT 1850 W -50...220 0,3 10,4 18,5 5,8 - 90 - 9,0 - 400; 3PE; 50 LWP 532
LAUDA Integral XT 1850 WS -50...220 0,3 16,0 18,5 5,8 - 90 - 9 - 400; 3PE; 50 LWP 533
LAUDA Integral XT 150 -45...220 0,05 3,5 1,5 2,9 - 45 - 2,6 - 230; 50 LWP 112
LAUDA Integral XT 250 W -45...220 0,05 3,5 2,1 2,9 - 45 - 2,6 - 230; 50 LWP 113
LAUDA Integral XT 550 -50...200 0,05 5,3 5,0 2,9 - 45 - 5 - 400; 3/PE; 50 LWP 524
LAUDA Integral XT 550 W -50...200 0,1 5,3 5,4 2,9 - 45 - 5 - 400; 3/PE; 50 LWP 525
LAUDA Integral XT 1590 WS -90...200 0,3 8,0 15,0 2,9 - 45 - 10,5 - 400; 3PE; 50 LWP 551

> Integral


LAUDA Integral T 4600 -30...120 0,2 6,0 4,6 3,2 - 40 - 6...18 - 400; 3/N/PE 50 LWP 205
LAUDA Integral T 4600 W -30...120 0,2 6,0 5,5 3,2 - 40 - 6...18 - 400; 3/N/PE 50 LWP 206
LAUDA Integral T 7000 -30...120 0,3 6,0 7,0 6 - 60 - 8...20 - 400; 3/N/PE 50 LWP 207
LAUDA Integral T 7000 W -30...120 0,3 6,0 8,5 6 - 60 - 8...20 - 400; 3/N/PE 50 LWP 208
LAUDA Integral T 10000 -30...120 0,3 9,0 10,0 6 - 60 - 8...20 - 400; 3/N/PE 50 LWP 209
LAUDA Integral T 10000 W -30...120 0,3 9,0 13,0 6 - 60 - 8...20 - 400; 3/N/PE 50 LWP 210
LAUDA Integral T 1200 -25...120 0,2 2,3 1,2 3,2 - 40 - 3...7 - 230; 50 LWP 101
LAUDA Integral T 1200 W -25...120 0,2 2,3 1,6 3,2 - 40 - 3...7 - 230; 50 LWP 102
LAUDA Integral T 2200 -25...120 0,2 2,3 2,2 3,2 - 40 - 3...7 - 230; 50 LWP 103
LAUDA Integral T 2200 W -25...120 0,2 2,3 2,7 3,2 - 40 - 3...7 - 230; 50 LWP 104